3 Touch Probe Cycles for Automatic Workpiece Inspection

3.3 A

u

to

matic W

o

rk

piece Measur

ement

MEAS. RECTAN. INSIDE (touch probe cycle 423,
DIN/ISO: G423)

Touch probe cycle 423 finds the center, length and width of a
rectangular pocket. If you define the corresponding tolerance values in
the cycle, the TNC makes a nominal-to-actual value comparison and
saves the deviation value in system parameters.

1

The TNC positions the touch probe to the starting points at rapid
traverse (value from MP6150 or MP6361) following the positioning
logic (see “Running touch probe cycles” on page 26) to the
starting point

1

. The TNC calculates the probe starting points from

the data in the cycle and the safety clearance from MP6140.

2

Then the touch probe moves to the entered measuring height and
probes the first touch point at the probing feed rate (MP6120 or
MP6360).

3

Then the touch probe moves either paraxially at the measuring
height or linearly at the clearance height to the next starting point

2

and probes the second touch point.

4

The TNC positions the probe to starting point

3

and then to starting

point

4

to probe the third and fourth touch points.

5

Finally the TNC returns the touch probe to the clearance height and
saves the actual values and the deviations in the following Q
parameters:

X

Y

1

2

3

4

Parameter number

Meaning

Q151

Actual value of center in reference axis

Q152

Actual value of center in minor axis

Q154

Actual value of length in the reference axis

Q155

Actual value of length in the minor axis

Q161

Deviation from center of reference axis

Q162

Deviation from center of minor axis

Q164

Deviation of length in reference axis

Q165

Deviation of length in minor axis

Before programming, note the following

Before a cycle definition you must have programmed a
tool call to define the touch probe axis.

If the dimensions of the pocket and the safety clearance
do not permit pre-positioning in the proximity of the touch
points, the TNC always starts probing from the center of
the pocket. In this case the touch probe does not return to
the clearance height between the four measuring points.