3 a u to matic w o rk piece measur ement – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 142

142
3 Touch Probe Cycles for Automatic Workpiece Inspection
3.3 A
u
to
matic W
o
rk
piece Measur
ement
1st measuring point in 1st axis
Q263 (absolute):
coordinate of the first touch point in the reference
axis of the working plane.
1st measuring point in 2nd axis
Q264 (absolute):
coordinate of the first touch point in the minor axis of
the working plane.
1st measuring point in 3rd axis
Q294 (absolute):
coordinate of the first touch point in the touch probe
axis.
2nd measuring point in 1st axis
Q265 (absolute):
coordinate of the second touch point in the reference
axis of the working plane
2nd measuring point in 2nd axis
Q266 (absolute):
coordinate of the second touch point in the minor axis
of the working plane
2nd measuring point in 3rd axis
Q295 (absolute):
coordinate of the second touch point in the touch
probe axis.
3rd measuring point in 1st axis
Q296 (absolute):
coordinate of the third touch point in the reference
axis of the working plane.
3rd measuring point in 2nd axis
Q297 (absolute):
coordinate of the third touch point in the minor axis of
the working plane.
3rd measuring point in 3rd axis
Q298 (absolute):
coordinate of the third touch point in the touch probe
axis.
Setup clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to MP6140.
Clearance height
Q260 (absolute): Coordinate in the
touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.
Measuring log
Q281: Definition of whether the TNC is
to create a measuring log:
0: No measuring log
1: Generate measuring log: with the standard setting
the TNC saves the log file TCHPR431.TXT in the
directory in which your measuring program is also
stored.
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.
Example: NC blocks
5 TCH PROBE 431 MEASURE PLANE
Q263=+20
;1ST POINT 1ST AXIS
Q264=+20
;1ST POINT 2ND AXIS
Q294=-10
;1ST POINT 3RD AXIS
Q265=+50
;2ND POINT 1ST AXIS
Q266=+80
;2ND POINT 2ND AXIS
Q295=+0
;2ND POINT 3RD AXIS
Q296=+90
;3RD POINT 1ST AXIS
Q297=+35
;3RD POINT 2ND AXIS
Q298=+12
;3RD POINT 3RD AXIS
Q320=0
;SET-UP CLEARANCE
Q260=+5
;CLEARANCE HEIGHT
Q281=1
;MEASURING LOG
X
Y
Q297
Q263
Q264
Q266
Q296
Q265
X
Z
Q295
Q298
Q294
Q260
MP6140
+
Q320