HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 44

44
2 Touch probe cycles in the Manual and Electronic Handwheel modes
2.5 Measur
ing W
o
rk
pieces with a 3-D T
o
uc
h Pr
obe
To find the angle between the angle reference
axis and a side of the workpiece
Select the probe function by pressing the PROBING
ROT soft key.
Rotation angle: If you will need the current basic
rotation later, write down the value that appears
under Rotation angle.
Make a basic rotation with the side of the workpiece
(see “Compensating Workpiece Misalignment” on
page 35).
Press the PROBING ROT soft key to display the angle
between the angle reference axis and the side of the
workpiece as the rotation angle.
Cancel the basic rotation, or restore the previous basic
rotation.
This is done by setting the rotation angle to the value
that you previously wrote down.
To measure the angle between two workpiece sides:
Select the probe function by pressing the PROBING ROT soft key.
Rotation angle: If you will need the current basic rotation later, write
down the value that appears under Rotation angle.
Make a basic rotation with the side of the workpiece (see
“Compensating Workpiece Misalignment” on page 35).
Probe the second side as for a basic rotation, but do not set the
rotation angle to zero!
Press the PROBING ROT soft key to display the angle PA between
the two sides as the rotation angle.
Cancel the basic rotation, or restore the previous basic rotation by
setting the rotation angle to the value that you wrote down
previously.
PA
10
100
a?
a?
L?
X
Z
Y
100