63

3.1 Measur

ing W

o

rk

piece Misalignment

Center in 1st axis

Q321 (absolute value): Center of

the hole in the reference axis of the working plane.

Center in 2nd axis

Q322 (absolute value): Center of

the hole in the minor axis of the working plane. If you
program Q322 = 0, the TNC aligns the hole center to
the positive Y axis. If you program Q322 not equal to
0, then the TNC aligns the hole center to the nominal
position (angle of the hole center).

Nominal diameter

Q262: Approximate diameter of the

circular pocket (or hole). Enter a value that is more
likely to be too small than too large.

Starting angle

Q325 (absolute): Angle between the

reference axis of the working plane and the first touch
point.

Stepping angle

Q247 (incremental): Angle between

two measuring points. The algebraic sign of the
stepping angle determines the direction of rotation
(negative = clockwise) in which the touch probe
moves to the next measuring point. If you wish to
probe a circular arc instead of a complete circle, then
program the stepping angle to be less than 90°.

X

Y

Q322

Q321

Q262

Q325

Q247

The smaller the angle, the less accurately the TNC can
calculate the circle center. Minimum input value: 5°.