background image

Chapter 8. Maintenance

8-10

707157-001

Replacing the Power Supply

The redundant 800W power supplies used by the CNA-8000 can each
provide adequate power to satisfy all the requirements of the unit. If
either supply fails, the remaining supply is capable of supplying power
until the failing supply is replaced. These modules may be replaced
without removing the cover, and are hot-swappable. Replace with the
same model (Visara p/n 54136-001).

Accessing the 800W Power Supply

Caution: Before removing a power supply module, unplug the AC

power cord first from the AC power source then from the
power supply module that is to be replaced.

Procedures

1. Locate the release tab on the left side of the power supply that is

being replaced.

2. Push the release tab to the right to release the power supply from

its locking position as shown below:

3. Once the power supply module is released from its locking

position, remove it from the chassis.