Bus acg13 od, Bus tag16 50 – Measurement Computing Analyzer488 User Manual
Page 25

Section 2
Getting Started
2.3
Enter the following commands at the keyboard controller prompt (CMD>) and
observe the Analyzer488 display:
SRQ
IFC
REN
ATN
EOI
LOCATION
MESSAGE
CMD> output 16;F0R0X
BUS
ACG13 OD
¼
¼
CMD> enter 16;eoi
BUS
TAG16 50
¼
¼
NDCV-000.0156E-3
The display of the Analyzer488 after each command shows the last byte that was
transferred on the bus. Although you only see the last data byte, several bytes were
transferred. To view each transaction at at readable rate, set the handshake speed to
Slow by pressing the [SLOW] key. Set the rate to 3 bytes per second by pressing the
[SHIFT] key followed by the [SLOW] key. Use the curosr keys to select a rate of 3
steps per second then press [ENTER].
Enter the same commands to the keyboard controller. Observe the Anlayzer488
display and you will see the bus activity at 3 bytes per second:
SRQ
IFC
REN
ATN
EOI
LOCATION
MESSAGE
CMD> output 16;F0R0X
BUS
TAG21
55
¼
¼
BUS
UNL
3F
¼
¼
BUS
LAG21 30
¼
¼
BUS
'F' 46
¼
BUS
'0' 30
¼
BUS
'R' 52
¼
BUS
'0' 30
¼
BUS
'X' 58
¼
BUS
CR OD
¼
¼
BUS
ACG13 OD
¼
¼