beautypg.com

Timeout – Measurement Computing Analyzer488 User Manual

Page 181

background image

Section 4

Serial Controller

4.87

TIMEOUT

The TIMEOUT command sets the number of seconds that the Analyzer488 will

wait for a bus event before declaring a time out error. The Analyzer488 checks for
time out errors on every byte it transfers, including command bytes. When using the
KEY

command, the Analyzer488 will wait the TIMEOUT period for a keypress.

Time out checking may not be suppressed however it may be set to a maximum

time of about 18 hours.

The query command TIMEOUT? returns the current timeout value.

TYPE

System command

SYNTAX

TIMEOUT[;][n]

n

is the number of seconds to allow in the range of 1 to 65535.

RESPONSE

None

MODE

Any

BUS STATES

None

QUERY

The string TIMEOUT followed by the timeout value.

RESPONSE

EXAMPLES

PRINT#1,"TIME OUT 10"

Wait 10 sec before time out

PRINT#1,"TIME OUT 3600"

Wait an hour before time out