Measurement Computing Analyzer488 User Manual
Page 166

Section 4
Serial Controller
4.72
[state]
state
is the state of a bus management line. A slash [/]
indicates unasserted, [X] means "don't care". The absence of a
slash
[/] or [X] means true (asserted). Any bus management
line is "don't care"
if not specified.
[line]
line
are bus management lines, one or more of: ATN, REN,
EOI
, IFC, SRQ, or ALL.
[byte]
Selects a bus data byte trigger condition. byte may be specified
in Binary (%01001010) (all eight digits must be specified),
Decimal (122), Hexadecimal (&H3F) (both digits must be
specified), or ASCII ('A). In binary or hexadecimal format, an
X
may be used to specify "don't care".
# OF MATCHES
[match count]
Skip match count occurrences of the trigger pattern before
recording data. match count is from 1 to 65,535.
TRIG DELAY
[delay count]
Skip delay count bus events after the trigger pattern
is matched before recording data. delay count is from 0 to
9,999,999.
POST COUNT
[post count]
Record post count bus events after match count
occurrences of the trigger pattern and delay count events
have
occurred. post count is from 0 to 32,767.
WHEN COMPLETE [STEP | STOP
]
Select the action taken at the end of the recording sequence. If
STEP
is selected, HANDSHAKE will be changed to STEP at the
end of
the recording sequence. If STOP is selected, data
recording will stop at the
end of the recording sequence and the
bus will run at the current
HANDSHAKE
speed.