Clear maintenance (cl ma) (1000 fleetkey only), Encode key (en ke) – Gasboy FMS KE200 User Manual
Page 44
KE200 Setup - Terminal
Clear Maintenance (CL MA) (1000 FleetKey only)
Page 38 MDE-4465A KE200 Key Encoder/Maintenance Terminal Operation Manual · October 2007
- “LO ID”, loads ID fields. The fields you configure must match the fields as you ordered
them. Consult your key layout.
- “LO FO”, loads formats for key encoding.
- “RES RE”, resets encoding records file.
- “RES TR”, resets maintenance transaction file.
- “LO TR”, loads the starting transaction number.
- “CL MA”, clears the maintenance table (1000 FleetKey only).
- “LO MA”, loads the maintenance table. This table must match the one defined in your
FleetKey system. (1000 FleetKey only).
Once the above steps are performed, your system is ready to encode keys and record
performed maintenance.
The following pages contain all terminal commands, in alphabetical order.
The symbol “
↵
” is shown in examples to denote that the “ENTER” key is pressed.
Clear Maintenance (CL MA) (1000 FleetKey only)
Use “CLEAR MAINTENANCE” when you start up your system or before the initial loading
of the maintenance table to clear out any residual information that may be present from factory
testing. Use the “CL MA” option with care as it deletes the entire maintenance table and loads
it with zeros.
To clear the maintenance table, proceed as follows:
1
At the asterisk prompt, type “CL MA” and press ENTER. The system responds with the
message, “CLEAR MAINTENANCE TABLE?
2
Type “Y” to clear or “N” not to clear and press ENTER. The system displays the message,
“COMMAND COMPLETED”.
Encode Key (EN KE)
Encoding your keys involves taking all the information you want on the key (from the
encoding form) and electronically writing it onto each key.
There are two methods for encoding: Formatted Encode and Unformatted Encode. A
Formatted Encode uses the field values loaded with the “LOAD FORMAT” command. An
Unformatted Encode prompts for every field and you must enter a value for each.