System Overview

Communications

Page 6 MDE-4465A KE200 Key Encoder/Maintenance Terminal Operation Manual · October 2007

The following table contains Poll Address Switch Settings for SW1-1 through SW1-4.

Address

SW1-1

SW1-2

SW1-3

SW1-4

01

CLOSED

CLOSED

CLOSED

CLOSED

02

OPEN

CLOSED

CLOSED

CLOSED

03

CLOSED

OPEN

CLOSED

CLOSED

04

OPEN

OPEN

CLOSED

CLOSED

05

CLOSED

CLOSED

OPEN

CLOSED

06

OPEN

CLOSED

OPEN

CLOSED

07

CLOSED

OPEN

OPEN

CLOSED

08

OPEN

OPEN

OPEN

CLOSED

09

CLOSED

CLOSED

CLOSED

OPEN

10

OPEN

CLOSED

CLOSED

OPEN

11

CLOSED

OPEN

CLOSED

OPEN

12

OPEN

OPEN

CLOSED

OPEN

13

CLOSED

CLOSED

OPEN

OPEN

14

OPEN

CLOSED

OPEN

OPEN

15

CLOSED

OPEN

OPEN

OPEN

16

OPEN

OPEN

OPEN

OPEN

Note: The poll address is the same for both Port 1 and Port 3 (internal modem port).

Position 5 on switch bank SW1 is used to select the communications mode for Port 1. When
position 5 is closed, the port operates in the Standard Terminal mode providing operator
prompts and messages. Activity through Port 1 is also sent to the logger port while Port 1 is in
the Terminal mode.

When position 5 is open, the Computer Mode interface is selected for Port 1. While in the
Computer mode, the port only responds to Computer mode command packets. Gasboy PC
software uses Computer mode to communicate with the KE200. Activity through Port 1 is not
sent to the logger port while it is set for Computer mode.

SW1-5

Definition

CLOSED

Terminal mode selected for Port 1

OPEN