External reference (cp3), Power entry, Ac power connector – Comtech EF Data SDM-300A User Manual
Page 93: 48vdc option, Ground connector (gnd), 9 external reference (cp3), 2 48vdc option, 11 ground connector (gnd)

SDM-300A Satellite Modem
Revision 6
External Connections
MN/SDM300A.IOM
4–15
4.1.9
External Reference (CP3)
CP3 is a BNC connector for an external reference. The input impedance is 75
Ω. For normal
operation, the reference signal is
≥
0 dBm.
Valid External Reference frequencies are 1, 5, 10, and 20 MHz.
4.1.10 Power
Entry
4.1.10.1
AC Power Connector
A standard, detachable, non-locking, 3-prong power cord (IEC plug) supplies the Alternating
Current (AC) power to the modem. Observe the following:
Input Power
55W maximum, 40W typical
Input Voltage
90 to 132 or 175 to 264 VAC
Unit switches ranges automatically
Connector Type
I.E.C
Fuse Protection
1A slo-blo
Line and neutral fusing
5 mm type fuses
4.1.10.2 48VDC
Option
Specifications include:
Input Power
55W maximum, 40W typical
Input Voltage
38 to 64 VDC
Connector Type
20A, 3 screw terminal block
Fuse Protection
2A slo-blo
4.1.11
Ground Connector (GND)
A #10-32 stud on the rear panel of the modem is used for connecting a common chassis ground
among all equipment.
Note: The AC power connector provides the safety ground.