Comtech EF Data SDM-300A User Manual
Page 448

SDM-300A Satellite Modem
Revision 6
Remote Control Operation
MN/SLM3650.IOM
A–56
(Note 16)
(Note 16)
(Note 15)
(Note 15)
99
100
101
102
103
104
105
106
(Note 5)
(Note 6)
107
108
109
110
111
112
AUPC EBN0 Target Set Point
(ref. 'ENSP_' command).
AUPC Max. Tracking Rate
(ref. 'MAXT_' command).
AUPC Local Carrier Loss
(ref. 'LCL_' command).
AUPC Remote Carrier Loss
(ref. 'RCL_' command).
reserved null field.
reserved null field.
Transmit BPSK Data Ordering
(ref. 'TDA_' command).
Receive BPSK Data Ordering
(ref. 'RDA_' command).
RTS TX-IF Control Mode
(ref. 'RTSM_' command).
CTS Delay Time
(ref. 'CTSD_' command).
Carrier Only Mode
(ref. 'COM_' command).
IDR TX ESC Type
(ref. 'TET_' command).
IDR RX ESC Type
(ref. 'RET_' command).
TX Reed-Solomon Interleave Value
(ref. 'TRSI_' command).
p99 = nn.n, where 'nn.n' EBN0 Target Set Point in dB.
p100 = n.n, where 'n.n' is the Max. Tracking Rate in dB/Min.
p101 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2'
(MAXIMUM).
p102 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2'
(MAXIMUM).
p105 = n, where 'n' is '0' (NRM), '1' (INV).
p106 = n, where 'n' is '0' (NRM), '1' (INV).
p107 = n, where 'n' is '0' (off) or '1' (on).
p108 = nn, CTS delay time in seconds.
p109 = n, where 'n' is '0' (OFF),'1' (CENTER-CW), '2'
(DUAL-CW), '3' (OFFSET-CW).
p110 = n, where 'n' is '0' (AUDIO), '1' (DATA).
p111 = n, where 'n' is '0' (AUDIO), '1' (DATA).
p112 = nn, Interleave value.