A.18bulk consolidated status, A.18 bulk consolidated status – Comtech EF Data SDM-300A User Manual
Page 441

SDM-300A Satellite Modem
Revision 6
Remote Control Operation
MN/SLM3650.IOM
A–49
A.18
Bulk Consolidated Status
This command causes bulk modem status to be returned. To reduce the length of the response, message parameter
data are returned without identifiers. However, parameter identification can be determined by order of return. Each
status parameter is terminated with a ',' (comma) except for the last parameter which has the standard message
termination sequence ('cr''lf']). Most of the data returned is formatted the same way as the single command status
request (refer to the appropriate portions of this document in preceding sections). Additional configuration status of
new options and features will always be appended to the end.
Bulk Consol.
Status
Command:
Response:
Where 'pn' is the last parameter returned.
Parameter
Number
Parameter Name
(Command Reference)
Description
1
2
3
4
5
6
7
8
9
10
Modulator RF output
(ref. 'RF_' command).
Modulator IF frequency
(ref. 'MF_' command).
Modulator rate
(ref. 'MR_' command).
Modulator preset 'A' assignment
(ref. 'ARMA_' command).
Modulator preset 'B' assignment
(ref. 'ARMB_' command).
Modulator preset 'C' assignment
(ref. 'ARMC_' command).
Modulator preset 'D'
(ref. 'ARMD_' command).
Modulator preset 'V' assignment
(ref. 'ARMV_' command).
Modulator power offset
(ref. 'MPO_' command).
Modulator output power level
(ref. 'MOP_' command).
p1 = n, where 'n' is '0' (off) or '1' (on).
p2 = nnn.nnnnnn, IF frequency in MHz.
p3 = nnnn_mmmm.mmm, code rate/data rate in kbps.
p4 = nnnn_mmmm.mmm, code rate/data rate in kbps.
p5 = nnnn_mmmm.mmm, code rate/data rate in kbps.
p6 = nnnn_mmmm.mmm, code rate/data rate in kbps.
p7 = nnnn_mmmm.mmm, code rate/data rate in kbps.
p8 = nnnn_mmmm.mmm, code rate/data rate in kbps.
p9 = snn.n, modulator power offset in dB.
p10 = snn.n, transmitter output power level in dBm.