A.20miscellaneous status, A.20, Miscellaneous – Comtech EF Data SDM-300A User Manual
Page 456: Status

SDM-300A Satellite Modem
Revision 6
Remote Control Operation
MN/SLM3650.IOM
A–64
A.20
Miscellaneous
Status
Change
Status
Command:
Response:
Where:
The 'x' character is defined as follows:
'@' = no change since last BCS_ and BCSF_ polls.
'A' = BCS_ response has changed since last BCS_ poll.
'B' = BCSF_ response has changed since last BCSF_ poll.
'C' = Both responses have changed since last BCS_ and
BCSF_ polls.
This command indicates that a change has or has not occurred
on either the BCS_ or the BCSF_ response since the last
BCS_ or BCSF_ poll.
Equipment
Type
Command:
Response:
Where:
tttttttt = Equipment type.
xxx.yyy.zzz = Software version.
Monitor &
Control
Firmware
Information
Command:
Response:
VER_xxx.yyy.zzz'cr'
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr''lf']
Where:
xxx.yyy.zzz = Software version number (0.0.0 to 999.999.999).
nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).
DATA ROM
Firmware
Information
Command:
Response:
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr'
TURBO: FW/nnnnnn-ddr’cr’’lf’]
Where:
nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).
Notes:
1.
If Dash number is not used, '-dd' will be reported.
2.
Turbo FW information returned only if TPC PCB is
installed