Function select: faults/alarms: modulator, Function select: faults/alarms: demodulator, Modulator – Comtech EF Data SDM-300A User Manual
Page 155: Demodulator

SDM-300A Satellite Modem
Revision 6
Front Panel Operation
MN/SDM300A.IOM
5–61
FUNCTION SELECT: FAULTS/ALARMS: MODULATOR
MODULATOR
---------
IF SYNTHESIZER
Modulator IF synthesizer fault.
DATA CLOCK SYN
Transmit clock synthesizer fault. Indicates the internal Voltage Controlled
Oscillator (VCO) has not locked to the incoming data clock.
I CHANNEL
I channel data activity fault.
Q CHANNEL
Q channel data activity fault.
AGC LEVEL
TX IF AGC level fault.
MODEM REF ACT
MODEM REF activity alarm.
MODEM REF PLL
MODEM REF PLL not locked.
MODULE
Modulator module fault.
CONFIGURATION
Modulator configuration fault.
FUNCTION SELECT: FAULTS/ALARMS: DEMODULATOR
DEMODULATOR
+------
CARRIER DETECT
Carrier detect fault. Indicates the decoder is not locked.
IF SYNTHESIZER
Demodulator IF synthesizer fault. Indicates the IF synthesizer is not locked.
I CHANNEL
I channel activity fault. Indicates a loss of activity in the I channel of the
quadrature demodulator.
Q CHANNEL
Q channel activity fault. Indicates a loss of activity in the Q channel of the
quadrature demodulator.
BER THRESHOLD
Secondary alarm result of the BER threshold set in the DEMOD
Configuration menu.
MODULE
Demodulator/decoder module fault.
CONFIGURATION
Demodulator/decoder configuration fault.