Z80 Instruction Set
UM008007-0715
290
Z80 CPU
User Manual
Example
If the Program Counter contains
15B3h
, then upon the execution of an RST
18h
(object
code
1101111
) instruction, the PC contains
0018h
as the address of the next fetched op
code.
M Cycles
T States
4 MHz E.T.
3
11 (5, 3, 3)
2.75