Example
The Carry flag is set and it is required to jump back four locations from 480. The assembly
language statement is
JR
C
,
$
–
4
The resulting object code and final Program Counter value is shown in the following table:
Location Instruction
47C
← PC after jump
47D
–
47E
–
47F
–
480
38
481
FA (two’s
complement – 6)