Z80 Instruction Description

Z80 CPU

User Manual

265

Example

The Carry flag is set and it is required to jump back four locations from 480. The assembly
language statement is

JR

C

,

$

4

The resulting object code and final Program Counter value is shown in the following table:

Location Instruction

47C

← PC after jump

47D

47E

47F

480

38

481

FA (two’s

complement – 6)