Rrca – Zilog Z08470 User Manual
Page 219

UM008007-0715
Z80 Instruction Description
Z80 CPU
User Manual
207
RRCA
Operation
Op Code
RRCA
Operands
None.
Description
The contents of the Accumulator (Register A) are rotated right 1 bit position. Bit 0 is cop-
ied to the Carry flag and also to bit 7. Bit 0 is the least-significant bit.
Condition Bits Affected
S is not affected.
Z is not affected.
H is reset.
P/V is not affected.
N is reset.
C is data from bit 0 of Accumulator.
Example
The Accumulator contains the following data.
M Cycles
T States
4 MHz E.T.
1
4
1.00
CY
0
7
A
0
0
0
1
1
1
0
1
0F