UM008007-0715

Z80 Instruction Description

Z80 CPU

User Manual

203

RLCA

Operation

Op Code

RLCA

Operands

None.

Description

The contents of the Accumulator (Register A) are rotated left 1 bit position. The sign bit
(bit 7) is copied to the Carry flag and also to bit 0. Bit 0 is the least-significant bit.

Condition Bits Affected

S is not affected.

Z is not affected.

H is reset.

P/V is not affected.

N is reset.

C is data from bit 7 of Accumulator.

M Cycles

T States

4 MHz E.T.

1

4

1.00

CY

7

0

A

0

0

0

1

1

1

0

0

07