background image

Z80 Instruction Set

UM008007-0715

174

Z80 CPU
User Manual

NEG

Operation

A ← 0 – A

Op Code

NEG

Operands

None.

Description

The contents of the Accumulator are negated (two’s complement). This method is the
same as subtracting the contents of the Accumulator from zero.

The

80h

address remains unchanged.

Condition Bits Affected

S is set if result is negative; otherwise, it is reset.

Z is set if result is 0; otherwise, it is reset.

H is set if borrow from bit 4; otherwise, it is reset.

P/V is set if Accumulator was

80h

before operation; otherwise, it is reset.

N is set.

C is set if Accumulator was not

00h

before operation; otherwise, it is reset.

M Cycles

T States

4 MHz E.T.

2

8 (4, 4)

2.00

1

1

0

0

1

1

1

1

ED

0

1

0

0

0

1

0

0

44

Note: