Error management extension signals, Error management extension signals –11 – Altera RapidIO II MegaCore Function User Manual
Page 135

Chapter 5: Signals
5–11
Error Management Extension Signals
August 2014
Altera Corporation
RapidIO II MegaCore Function
User Guide
Packet and Error Monitoring Signal for the Transport Layer
Table 5–13
shows the packet and error monitoring signal for the Transport layer. For
Physical layer packet and error monitoring signals, refer to
Table 5–4 on page 5–3
.
Error Management Extension Signals
describe the signals that are added when you enable the Error
Management Extensions registers in the RapidIO II parameter editor. All of these
signals are clocked in the sys_clk clock domain.
Table 5–13. Transport Layer Packet and Error Monitoring Signal
Signal
Direction
Description
transport_rx_packet_dropped
Output
Pulsed high one Avalon clock cycle when a received packet is dropped by
the Transport layer. Examples of packets that are dropped include packets
that have an incorrect destination ID, are of a type not supported by the
selected Logical layers, or have a transaction ID outside the range used by
the selected Logical layers. For more information, refer to
Table 5–14. Error Setting Signals
Signal
Direction
Description
message_error_response_set
Input
Support user logic in setting the corresponding fields in the
Logical/Transport Layer Error Detect
CSR at offset
0x308, For information about the register fields these signals can
set, refer to
,
If your design does not use one or more of these signals, you
should tie the unused signals low.
gsm_error_response_set
Input
message_format_error_response_set
Input
illegal_transaction_decode_set
Input
illegal_transaction_target_error_
set
Input
message_request_timeout_set
Input
slave_packet_response_timeout_set
Input
unsolicited_response_set
Input
unsupported_transaction_set
Input
missing_data_streaming_context_
set
Input
open_existing_data_streaming_
context_set
Input
long_data_streaming_segment_set
Input
short_data_streaming_segment_set
Input
data_streaming_pdu_length_error_
set
Input