Diagnostic word

Operating Manual PNOZmulti 2 Communication Interfaces
1002971­EN­02

97

7

Diagnostic word

7.1

Introduction

A diagnostic word can be read out for those elements in the PNOZmulti Configurator that
can store a status. The diagnostic word contains information on a particular element, such
as:

}

Operating states (e.g. safety gate was opened)

}

Error messages (e.g. N/C contact failed to switch or switched too late)

7.2

Elements with diagnostic word

The diagnostic word is accessed by activating an Element ID. The permitted value range
for the Element ID is 1 ... 100. Elements with an element ID include:

}

Function elements

E­STOP and safety gate

Safety gate with guard locking

Light curtain

Enabling switch

Foot switch

Two­hand button

Operating mode selector switch

}

Logic elements

RS flip­flop

Start element

}

Press elements

Light curtain

}

Muting elements

Sequential muting

Parallel muting

Cross muting

}

Output elements

Output elements with feedback loop

Safety valve

7.3

Structure of the diagnostic word

The diagnostic word has 16 Bits:

Bit 15

Bit 14

...

Bit 2

Bit 1

Bit 0

If the diagnostic word = 0, the output of the respective element = 1. The element was en­
abled. (Exceptions: on various function elements, the states of the inputs are evaluate). 
Otherwise, at least one of the bits from 0 ... 15 of the diagnostic word is set and can be