beautypg.com

8 troubleshooting, 1 request format does not meet specifications, 2 error while executing a request – Pilz PNOZ m B0 User Manual

Page 44: Troubleshooting, Request format does not meet specifications, Error while executing a request

background image

Communication modules

Operating Manual PNOZmulti 2 Communication Interfaces
1002971­EN­02

44

5.8

Troubleshooting

5.8.1

Request format does not meet specifications

If the request format does not meet the specifications, the PNOZmulti 2 sends the following
response:

Byte

Response

0

0x05

1

0x02

2

0x00

3

0x02

4

0x00

5

0x02

6

0x10

5.8.2

Error while executing a request

If an error occurs while executing a request, the PNOZmulti 2 sends the following response:

Byte

Response

0

0x05

1

0x15

2

0x00

3

0x05

4

Error Code

5

0x00

6

0x00

7

0x00

8

BCC

9

0x10

Error Codes (Byte 4):

}

0x62: Request's BCC is incorrect

}

0x63: Request cannot be executed

}

0x64: Request unknown

}

0x67: Table or segment number unavailable

}

0x68: PNOZmulti 2 not ready