8 troubleshooting, 1 request format does not meet specifications, 2 error while executing a request – Pilz PNOZ m B0 User Manual
Page 44: Troubleshooting, Request format does not meet specifications, Error while executing a request

Communication modules
Operating Manual PNOZmulti 2 Communication Interfaces
1002971EN02
44
5.8
Troubleshooting
5.8.1
Request format does not meet specifications
If the request format does not meet the specifications, the PNOZmulti 2 sends the following
response:
Byte
Response
0
0x05
1
0x02
2
0x00
3
0x02
4
0x00
5
0x02
6
0x10
5.8.2
Error while executing a request
If an error occurs while executing a request, the PNOZmulti 2 sends the following response:
Byte
Response
0
0x05
1
0x15
2
0x00
3
0x05
4
Error Code
5
0x00
6
0x00
7
0x00
8
BCC
9
0x10
Error Codes (Byte 4):
}
0x62: Request's BCC is incorrect
}
0x63: Request cannot be executed
}
0x64: Request unknown
}
0x67: Table or segment number unavailable
}
0x68: PNOZmulti 2 not ready