1 example 1 - access successful, Example 1 access successful, Fieldbus modules – Pilz PNOZ m B0 User Manual
Page 16: Master fieldbus module

Fieldbus Modules
Operating Manual PNOZmulti 2 Communication Interfaces
1002971EN02
16
4.1.4.1
Example 1 Access successful
Access to existing segments
The Master requests segment 1 from table 23. The fieldbus module confirms both these de
tails and sends segment 1. Then the data from segment 5 table 21 is requested.
23
1
0
0
17
18
19
31
17
18
19
31
17
18
19
31
17
18
19
31
23
1
21
5
X
X
21
5
X
X
0
0
Master
Fieldbus module
This manual is related to the following products: