beautypg.com

8 process data, fieldbus - sdo index 0x2009, Process data, fieldbus ­ sdo index 0x2009 – Pilz PNOZ m B0 User Manual

Page 142

background image

Appendix

Operating Manual PNOZmulti 2 Communication Interfaces
1002971­EN­02

142

INFORMATION

The LED status "On" and "Flashes" cannot be determined exactly on many
fieldbus modules.

8.2.8

Process data, fieldbus ­ SDO Index 0x2009

Index (hex)

Size
(byte)

Content

Status of system LEDs for supply voltage and diagnostics.

Position of LED0 ­ LED3 of the fieldbus modules PNOZmulti

LED 0

LED 1

LED 2

LED 3

.......

For coding of LED status, see below.

Bit 7

Bit 4

Bit 3

Bit 0

0x2009:1

1

LED 1

LED 0

0x2009:2

1

LED 3

LED 2

0x2009:3

...

0x2009:80

126

Reserved

LED status

4 Bit coding

Off

0x0

On

0xF

Flashes

0x3

INFORMATION

The LED status "On" and "Flashes" cannot be determined exactly on many
fieldbus modules.