8 table 90 - device data, base unit, Table 90 device data, base unit – Pilz PNOZ m B0 User Manual
Page 119

Appendix
Operating Manual PNOZmulti 2 Communication Interfaces
1002971EN02
119
Segment
Byte
Content
3
0, 1
7th character of project name
2, 3
8th character of project name
4, 5
9th character of project name
6, 7
10th character of project name
8, 9
11th character of project name
10, 11
12th character of project name
12
Free
4
0, 1
13th character of project name
2, 3
14th character of project name
4, 5
15th character of project name
6, 7
16th character of project name
8, 9
End of character string (identified by "FFFF")
10, 11
Free
12
Free
8.1.8
Table 90 Device data, base unit
Table 90 consists of 3 segments, each of which has 13 Bytes. It contains the base unit's
device data.
Segment
Byte
Content
0
0 … 3
Product number 772 100: 000BC804 hex
}
Byte 0: 00
}
Byte 1: 0B,
}
Byte 2: C8,
}
Byte 3: 04
0
4 … 7
Serial number 123 456: 0001E240 hex.
}
Byte 4: 00
}
Byte 5: 01
}
Byte 6: E2,
}
Byte 7: 40
0
8, 9
Device type
PNOZ m B0: 0x0060
0
10, 11
Unit version 20: 14 hex
}
Byte 10: 00
}
Byte 11: 14
0
12
Free