Programming Reference

VERSAJET

US ` NUL

[Name]

Set communication configuration

[Format]

ASCII

US ` NUL n1 n2

Hex

1F 60 00 n1 n2

Decimal

31 96 00 n1 n2

[Range]

1 ≤ n1 ≤ 6 or n1 = 8, 9, 10, 11, 12, 14, 18, 255; 1 ≤ n2 ≤ 255

[Default]

n1 = 255; n2 = 1

[Description]

Select the communication interface(s) and set the idle timeout during which the current
active interface will be free after idling. You may refer to “Communication Session” on Page
2 of the Introduction Chapter for more details.

n1 specifies which communication interface is enabled. This member is a bit-wise OR of

any of the following values. If you want to enable all the interfaces, set n1 to 0xFF.

Bit

Function

Off/On

Hex

Decimal

Disable RS232

Off

00

0

0

Enable RS232

On

01

1

Disable

Off

00

0

1

Enable

On

02

2

Disable

Off

00

0

2

Enable

On

04

4

Disable

Off

00

0

3

Enable

On

08

8

Disable

Off

00

0

4

Enable

On

10

16

n2 : If the printer has stayed idle for n2 x 500 milliseconds, then the current active

interface will be free.