Cino M230B User Manual
Page 108

99
Programming Reference
VERSAJET
GS ( k PDF417
[Format]
ASCII
GS ( k pL pH cn fn n
Hex
1D 28 6B 03 00 30 43 n
Decimal
29 40 107 03 00 48 67 n
[Range]
(pL + pH x 256) = 3 (pL =3, pH =0)
cn = 48, fn = 67
1≤ n ≤ 5
[Default]
n = 2
[Description]
Specifies the width of a module of PDF417 symbol.
[Notes]
Settings of this function affect the processing of Functions 081.
The setting unit differs, depending on the printer models.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the
power is turned off.
The setting unit is 1 dot. The width is set in units of 0.125 mm {1/203 inch}.