Versajet rs u – Cino M230B User Manual
Page 211

202
Programming Reference
VERSAJET
RS u
[Name]
Execute macro
[Format]
ASCII
RS t n1 r t m
Hex
1E 75 n1 r t m
Decimal
30 117 n1 r t m
[Range]
1 ≤ n1 ≤ 8, 1 ≤ r ≤ 255, 0 ≤ t ≤ 255, 0 ≤ m ≤ 2
[Default]
None
[Description]
Execute macro
n1: Macro index no
r: Number of execution
t: Interval of execution
m: Operation mode
m
Description
0
Continuous
1
Feedkey
2
Present sensor
Executes a macro r times while waiting t x 100 msec for each macro execution, using
the mode specified by m as follows:
When m = 0, the macro executes r times continuously at the interval specified by t.