202

Programming Reference

VERSAJET

RS u

[Name]

Execute macro

[Format]

ASCII

RS t n1 r t m

Hex

1E 75 n1 r t m

Decimal

30 117 n1 r t m

[Range]

1 ≤ n1 ≤ 8, 1 ≤ r ≤ 255, 0 ≤ t ≤ 255, 0 ≤ m ≤ 2

[Default]

None

[Description]

Execute macro

n1: Macro index no

r: Number of execution
t: Interval of execution
m: Operation mode

m

Description

0

Continuous

1

Feedkey

2

Present sensor

Executes a macro r times while waiting t x 100 msec for each macro execution, using

the mode specified by m as follows:

When m = 0, the macro executes r times continuously at the interval specified by t.