Versajet us n – Cino M230B User Manual
Page 236
![background image](/manuals/734565/236/background.png)
227
Programming Reference
VERSAJET
US n
[Name]
Get battery status
[Format]
ASCII
US n
Hex
1F 6E
Decimal
31 110
[Return value]
Function
Length (Byte)
Value
Start byte
1
0x5F
Battery status
1
0x30: less than 10%
0x31: less than 20%
0x32: more than 20%
0x33: more than 30%
0x39: more than 90%
0x3A: 100%
End byte
1
0x00
[Description]
Battery check
[Notes]
This is a real-time command that the printer executes upon receiving it.
The printer returns 3 bytes, the first and last bytes are fixed values. Make sure the host
computer can receive data from receiving buffer.
This command setting is effective until ESC @ is executed, the printer is reset, or the
power is turned off.