Versajet gs ( k maxicode Page 122
Page 122
![background image](/manuals/734565/122/background.png)
113
Programming Reference
VERSAJET
GS ( k MaxiCode
[Format]
ASCII
GS ( k k pL pH cn fn n
Hex
1D 28 6B 03 00 32 41 n
Decimal
29 40 107 03 00 50 65 n
[Range]
(pL + pH x 256) = 3 (pL = 3, pH = 0)
cn = 50
fn = 65
50 ≤ n ≤ 54 ( 52~54 not support)
[Default]
n
= 50
[Description]
Specifies the mode of the MaxiCode
n
Function
50
Specify to mode 2.
51
Specify to mode 3.
[Notes]
Settings of this function affect the processing of Functions 281.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the
power is turned off.