beautypg.com

Versajet gs ( k datamatrix

Page 132

background image

123

Programming Reference

VERSAJET

GS ( k Datamatrix

[Format]

ASCII

GS ( k pL pH cn fn m d1…dk

Hex

1D 28 6B pL pH 37 50 30 d1…dk

Decimal

29 40 107 pL pH 55 80 48 d1…dk

[Range]

4≤ (pL + pH x 256) ≤4096 (0≤pL≤255, 0≤pH≤255)

cn = 55

fn = 80

m = 48

0 ≤d ≤255

k = (pL + pH x 256) – 3

[Description]

Stores the Datamatrix symbol data (

d1...dk

) in the symbol save area.

[Notes]

Data stored in the symbol save area by this function are processed by Function 781. The

data in the symbol save area are reserved after processing Function 781.

k

bytes of

d1...dk

are processed as symbol data.

Specify only the data code word of the symbol with this function. Be sure not to include

the following data in the data

d1...dk

because they are added automatically by the

printer.

Start pattern and stop pattern
Indicator code word of left and right
The descriptor of symbol length (the first code word in the data area)
The error correction code word calculated by modulus 929

Settings of this function are effective until the following processing is performed:

Function 080 or 180 or 280 or 780 or 880 or 980 is executed
ESC @ is executed
The printer is reset or the power is turned off