92

Programming Reference

VERSAJET

GS ( K

[Name]

Selects printing density

[Format]

ASCII

GS ( K pL pH fn m

Hex

1D 28 4B 02 00 31 m

Decimal

29 40 75 2 0 49 m

[Range]

(pL + pH x 256) = 2 (pL = 2, pH = 0)

fn = 49, 0 ≤ m ≤ 15

[Default]

m = 8

[Description]

Selects printing control mode by m.

m

Function

m < 8 Selects pale density
m = 8 Selects standard density
m > 8 Selects strong density

[Notes]

When a standard mode is selected, all the data in a line is printed in the same density.

When a page mode is selected, all the data printed collectively by FF or ESC FF is

printed in the same density.