beautypg.com

Versajet rs t – Cino M230B User Manual

Page 210

background image

201

Programming Reference

VERSAJET

RS t

[Name]

Define flash macro

[Format]

ASCII

RS t n d1…..dk RS t

Hex

1E 74 n d1…..dk 1E 74

Decimal

30 116 n d1…..dk 30 116

[Range]

1 ≤ n ≤ 8; k ≤ 8186

[Default]

None

[Description]

Define flash macro.

[Notes]

Macro definition starts when this command is processed during normal operation and

ends when it is processed during macro definition.

While the macro is defined, the printing is also executed.

The maximum data size to be defined as a macro is 8 KB. If the macro definition

exceeds the maximum data size, this command will not be processed, and the LED1
indicator blinks red, the LED2 and LED3 indicators blink green, LED4 indicators blinks
red (means ‘Command Error’).

The macro is executed by RS u.

If the printer processes this command, it will save the macro definition into flash.

The macro can be executed repeatedly after it is defined.

The defined contents of the macro are not cleared by ESC @.

The following commands cannot be contained in a macro. Do not use these commands

while the macro is being defined: FS q, GS ^, and GS v 0.

Excessive use of this function may destroy the non-volatile memory. As a guideline, do

not use this command more than 10 times per day for writing data to the non-volatile
memory.