Versajet – Cino M230B User Manual
Page 174
![background image](/manuals/734565/174/background.png)
165
Programming Reference
VERSAJET
m
Bar code
system
Number of
data (k, n)
Number of
characters
Characters
Character code (d)
0 UPC-A
Fixed
11 ≤ k ≤12
0~9
48 ≤ d ≤ 57
1 UPC-E
Fixed
11 ≤ k ≤12
0~9
48 ≤ d ≤ 57
2 JAN13
(EAN13)
Fixed
12 ≤ k ≤13
0~9
48 ≤ d ≤ 57
3 JAN8 (EAN8) Fixed
7 ≤ k ≤8
0~9
48 ≤ d ≤ 57
4 CODE39
Can be changed 1 ≤ k
0~9, A~Z SP, $, %,
*, +, -, ., / *
(start/stop
character)
48 ≤ d ≤ 57, 65 ≤ d ≤ 90, d= 32,
36, 37, 42, 43, 45, 46, 47 d= 42
(start/stop character)
5
ITF
(Interleaved 2
of 5)
Can be changed 1 ≤ k (even
number)
0~9
48 ≤ d ≤ 57
1
6 CODABAR
(NW7)
Can be changed 1 ≤ k
0~9, A~D $, +, -, ., /,: 48 ≤ d ≤ 57, 65 ≤ d ≤ 68, d= 36,
43, 45, 46, 47, 58
65 UPC-A
Fixed
11 ≤ n ≤12
0~9
48 ≤ d ≤ 57
66 UPC-E
Fixed
11 ≤ n ≤12
0~9
48 ≤ d ≤ 57
67 JAN13
(EAN13)
Fixed
12 ≤ n ≤13
0~9
48 ≤ d ≤ 57
68 JAN8 (EAN8) Fixed
7 ≤ n ≤8
0~9
48≤ d ≤57
69 CODE39
Can be changed 1 ≤ n ≤255
0~9, A~Z SP, $, %,
*, +, -, ., / *
(start/stop
character)
48 ≤ d ≤ 57, 65 ≤ d ≤ 90, d= 32,
36, 37, 42, 43, 45, 46, 47 d= 42
(start/stop character)
70
ITF
(Interleaved 2
of 5)
Can be changed 1 ≤ n ≤255 (even
number)
0~9
48 ≤ d ≤ 57
71 CODABAR
(NW7)
Can be changed 1 ≤ n ≤ 255
0~9, A~D $, +, -, .,
/, :
48 ≤ d ≤ 57, 65 ≤ d ≤ 68, d= 36,
43, 45, 46, 47, 58
72 CODE93
Can be changed 1 ≤ n ≤ 255
NUL~SP(7FH)
0 ≤ d ≤ 127
2
73 CODE128
Can be changed 2 ≤ n ≤ 255
NUL~SP(7FH)
0 ≤ d ≤ 127