Versajet us g – Cino M230B User Manual
Page 221

212
Programming Reference
VERSAJET
US G
[Name]
Buzzer control
[Format]
ASCII
US G n
Hex
1F 47 n
Decimal
31 71 n
[Range]
0≤ n ≤255
[Default]
n = 255
[Description]
Turn buzzer on/off, using n as follows:
Bit
Function
Off/On
Hex
Decimal
Disable Power on/off beep
Off
00
0
0
Enable Power on/off beep
On
01
1
Disable Battery-low on/off beep
Off
00
0
1
Enable Battery-low beep
On
02
2
Disable error beep
Off
00
0
2
Enable error beep
On
04
4
Disable radio link beep
Off
00
0
3
Enable radio link beep
On
08
8
4~7 Reserved
Off
00
0
[Notes]
Please note that n = 0 mutes all sounds
— not only the beeps listed above, but also Feed