Programming Reference

VERSAJET

RS J

[Name]

Rewind command (back feed)

[Format]

ASCII

RS J n

Hex

1E 4A n

Decimal

30 74 n

[Range]

10 ≤ n ≤100, the unit is 0.1mm.

[Default]

None

[Description]

Rewind command (back feed)

[Notes]

This command is used to make motor rewind.

The paper feed back is ended when no paper is detected.