143

Programming Reference

VERSAJET

GS :

[Name]

Start/end macro definition

[Format]

ASCII

GS :

Hex

1D 3A

Decimal

29 58

[Range]

None

[Default]

None

[Description]

Starts or ends macro definition

[Notes]

Macro definition starts when this command is processed during normal operation and

ends when it is processed during macro definition.

While the macro is defined, the printing is also executed.

The maximum data size to be defined as a macro is 2 KB. If the macro definition

exceeds the maximum data size, this command will not be processed, and the LED1
indicator blinks red, the LED2 and LED3 indicators blink green, LED4 indicators blinks
red (means ‘Command Error’).

The macro is executed by GS ^.

If the printer processes this command, it will save the macro definition into RAM. The

macro can be executed repeatedly after it is defined.

The defined contents of the macro are not cleared by ESC @. Defined content of the

macro is effective until the printer is reset, or the power is turned off.

Macro is not defined when the power is turned on.

The following commands cannot be contained in a macro. Do not use these commands

while the macro is being defined: FS q, GS ^, and GS v 0.