Unstructured E3-3 SAM
Table 7-15: Unstructured E3-3 SAM Alarm Configuration
Follow the sequence below to set network alarms. E3 alarms are set on a port basis with
alarm definitions as shown.
Network Alarms
Options
Service Alarms
Cell Starvation
Ignore/Major/Minor
LOS
LOF
Ignore/Major/Minor
LOF
AIS
Ignore/Major/Minor
AIS
RDI
Ignore/Major/Minor
RDI
Sequence Errors
Ignore/Major/Minor
Line Code Violation
Excessive SNP Errors
Ignore/Major/Minor
Excessive F-bit Errors
Excessive F-bit Errors
Ignore/Major/Minor
Excessive Parity Errors
Excessive Parity Errors
Ignore/Major/Minor
Excessive FEBE Errors
Excessive FEBE Errors
Ignore/Major/Minor
Select System Management
↵
Select Configure
↵
Select Slot with DS3
↵
Select Port of interest
↵
Adjust settings using the spacebar
↵
Select Alarm Configuration
↵
Select Network Alarms
↵
Select Escape and save settings as desired
↵
Press Service Alarms
↵
Repeat the procedure to set and save Service Alarms
↵