beautypg.com

General properties, General properties -20 – Carrier Access Broadmore 1750 User Manual

Page 134

background image

7-20

Broadmore 1750 - Release 4.6

Configuration

General Properties

General Properties

Max VP/VC

... 7-20

Bandwidth Meter

... 7-22

Max VP/VC

The Max VP/VC option allows you to set the maximum number of Virtual Paths
(VPs) and corresponding Virtual Channels (VCs). The maximum number of VCs
allowed per VP is based on the number of VPs set. Table 7-1 shows the Max VP/
VC settings and the valid values for VP and VC numbering.

Table 7-1: Settings for Max VP/VC and Valid Values for VP/VC Numbering

*VC numbering must start at 32 if the VP number is 0.
**For the ATM DS3, CBI, and HSSI-CBI modules, the VP number must be 0; 1 is invalid.

Max VP/VC

Setting

Maximum

Number of

VPs Allowed

Valid Values

for VP

Numbering

Maximum

Number of

VCs Allowed

Valid Values

for VC

Numbering*

2/65536

1

0 or 1**

65,535

1 - 65535

4/32768

4

0 - 3

32,767

1 - 32767

8/16384

8

0 - 7

16,383

1 - 16383

16/8192

16

0 - 15

8,191

1 - 8191

32/4096

(default)

32

0 - 31

4,095

1 - 4095

64/2048

64

0 - 63

2,047

1 - 2047

128/1024

128

0 - 127

1,023

1 - 1023

256/512

256

0 - 255

511

1 - 511