Configuration – Carrier Access Broadmore 1750 User Manual
Page 160

7-46
Broadmore 1750 - Release 4.6
Configuration
Unstructured DS3 SAM
Table 7-4: Unstructured DS3 SAM Alarm Configuration
Follow the sequence below to set network alarms. DS3 alarms are set on a port basis
with alarm definitions as shown.
Network AIS
Activate/Deactivate
Sends Alarm Indication Signal to the network
when activated.
Service AIS
Activate/Deactivate
Sends Alarm Indication Signal to the
connected local service equipment when
activated.
Loopback
Normal
Local
Remote
Normal is no loopback.
Local sets a service side loopback (DS3) on the
port.
Remote sets a network side loopback (ATM)
on the port.
See diagram “Loopback Options” on page 5-20
Network Alarms
Options
Service Alarms
Cell Starvation
Ignore/Major/Minor
LOS
LOF
Ignore/Major/Minor
LOF
AIS
Ignore/Major/Minor
AIS
Idle
Ignore/Major/Minor
Idle
RAI
Ignore/Major/Minor
RAI
FEAC
Ignore/Major/Minor
FEAC
Sequence Errors
Ignore/Major/Minor
Line Code Violation
Excessive SNP Errors
Ignore/Major/Minor
Excessive SNP Errors
Excessive F-bit Errors
Ignore/Major/Minor
Excessive F-bit Errors
Excessive Parity Errors
Ignore/Major/Minor
Excessive Parity Errors
Excessive C-bit Errors
Ignore/Major/Minor
Excessive C-bit Errors
Excessive FEBE Errors
Ignore/Major/Minor
Excessive FEBE Errors
Item
Options
Comments