Static routes, Static routes -16 – Carrier Access Broadmore 1750 User Manual
Page 130

7-16
Broadmore 1750 - Release 4.6
Configuration
Static Routes
Static Routes
Each Broadmore 1750 has an additional Ethernet route to support RFC 1577 unless it
is on the same Ethernet network as the master control station. Follow the steps below
to add this routing. For sample configuration with static routes, see “Sample Network
with RFC 1577 Configuration” on page
1. Connect to the Broadmore 1750 via the serial port and log-in using the default
user ID and password, SYSADMIN and INITIAL.
2. This will give you the prompt: Broadmore>
Enter route –a
↵ to display the current routing table.
3. Add a routing entry in the format
route add xxx.xxx.xxx.xxx yyy.yyy.yyy.yyy
↵
where xxx.xxx.xxx.xxx is the destination IP address (control station)
yyy.yyy.yyy.yyy is the ATM subnet IP address of the Broadmore 1750 on the
Ethernet segment serving as the control station.
4. Enter savert
↵ to save this entry. The new routing entry is immediately
active.
5. Enter route –a
↵ to observe that the route has been added to the table.
NOTE:
You may enter route delete xxx.xxx.xxx.xxx yyy.yyy.yyy.yyy
to remove the entry from the routing table.
6. Enter cammi
↵ to return to CAMMI.
Repeat this procedure for each Broadmore 1750.