Carrier Access Broadmore 1750 User Manual
Page 167
Broadmore 1750 - Release 4.6
7-53
Configuration
Structured DS3 SAM
Table 7-9: Structured DS3 SAM Alarms
Automatic FEAC
Alarms
Activate/Deactivate
Activates or deactivates Far End Alarm and Control
Channel (FEAC) alarms. FEAC alarms can only be active
when the port is configured for C-bit parity framing.
Activate to detect and transmit RAI as applicable and detect
FEAC channel activate/deactivate commands
Service FEAC
Loopback
Activate/Deactivate
Activate sends a FEAC command to the far end service
equipment to go into service loopback. Deactivate sends a
FEAC command to go out of service loopback. Only active
when port is configured for C-bit parity.
Service AIS
Activate/Deactivate
Sends Alarm Indication Signal to the connected local
service equipment when activated.
Service Alarms
Options
LOS
Ignore/Major/Minor
LOF
Ignore/Major/Minor
AIS
Ignore/Major/Minor
Idle
Ignore/Major/Minor
RAI
Ignore/Major/Minor
FEAC
Ignore/Major/Minor
Line Code Violation
Ignore/Major/Minor
Excessive F-bit Errors
Ignore/Major/Minor
Excessive Parity Errors
Ignore/Major/Minor
Excessive C-bit Errors
Ignore/Major/Minor
Excessive FEBE Errors
Ignore/Major/Minor
Item
Options
Description