Carrier Access Broadmore 1750 User Manual
Page 166

7-52
Broadmore 1750 - Release 4.6
Configuration
Structured DS3 SAM
Table 7-8
:
Structured DS3 SAM Diagnostics Configuration
Item
Options
Description
Port Name
A descriptive field to identify the port
Port Mode
On-line
Off-line
 
This is a status field that can be toggled to offline, in which 
case the port will not be available to make calls and passive 
SVCs are refused.
Framing
C-bit
M13
C-bit is a framing mode using DS2 stuff bits associated 
with M13 multiplexing for other purposes such as Far End 
Alarm Control (FEAC) Channel. 
M13 is a mode that maps 28 DS1s directly into the DS3. 
The DS1s do not exist independently as is the case when 
M23 multiplexing is used. 
Clock Mode
Network
BITS-Clock
Loop
(Synchronous) Network-This method of clock recovery 
derives timing from the ATM Network and propagates it to 
the CE Service Interface. The ATM network must be 
synchronized to a single source clock. User equipment 
should be configured to recover timing from the Broadmore 
1750 CE service interface.
BITS-Clock (Building Integrated Timing Supply)- 
distributes standard timing to equipment within the central 
office. The Broadmore 1750 accepts BITS via either NIM 
IOM. The fallback for the primary BITS clock is the other 
BITS clock. The fallback for no BITS is the internal clock 
of the NIM.
(Synchronous) Loop-The Broadmore 1750 CE interface 
will derive clock from the attached SDS3 user equipment 
and transmit from the CE interface at that rate. The user 
equipment should be configured for Internal timing if the 
Broadmore 1750 CE service interface is configured for 
Synchronous loop.
Loopback
Normal
Remote
Normal Mode is no loopback. 
Remote Loopback sets a loopback to the service side.
Service RAI
Auto
X-bits 1
X-bits 0
Indication (RAI) configuration. Allows user configuration 
of the X-bits associated with C-bit parity framing. Auto 
makes it transparent; the other choices set the X-bits to 
either 1 or 0.