Optical interface connections, Optical interface connections -6, Warning – Carrier Access Broadmore 1750 User Manual
Page 104

6-6
Broadmore 1750 - Release 4.6
Electrical Installation
Optical Interface Connections
Optical Interface Connections
The Broadmore 1750 interfaces to an ATM network via fiber optic cable
using SC connectors on the front panel of the OC-12c NIMs.
1. Route the cable to the front of the chassis.
2. Route the cable into the chassis via the small square opening on the
lower-right, front cover of the chassis.
3. Connect the cables to the labeled TX and RX connectors on the
front of the NIM. (See example at right.)
4. Use the plastic cable guides and cable protector shipped with the
Broadmore 1750 to secure the cable.
WARNING!
U
NTERMINATED
OPTICAL
CONNECTIONS
MAY
EMIT
LASER
RADIATION
. D
O
NOT
VIEW
BEAM
WITH
OPTICAL
INSTRUMENT
.
OC 12
RX
TX
LOS
ON-LINE
FAULT
7 6 6 0 - 1 1 4