Cammi access, Cammi access -7 – Carrier Access Broadmore 1750 User Manual
Page 121
Broadmore 1750 - Release 4.6
7-7
Configuration
CAMMI Access
CAMMI Access
To access the CAMMI main menu, log into the system with a valid user identification
(SYSADMIN) and password (INITIAL). This default user ID/password is delivered
with the system with supervisor access as explained in “General Properties” on
page
. User ID and password are case-sensitive when entered.
At this point, you may change the terminal interface baud rate. The default is 9600 baud
and the system reverts to this at every reboot. The command to change the rate is
setbaud
57600, or 115200.
NOTE:
The baud rate default is 9600. The terminal will return to 9600
baud on each system boot or reboot. Operation above 19200 is not
recommended.
Upon successful entry, you are asked to change the terminal baud rate to match the new
setting. The system will then change its baud rate. You will not be able to communicate
with the system until your terminal baud rate is changed to match.