Carrier Access Broadmore 1750 User Manual
Page 159

Broadmore 1750 - Release 4.6
7-45
Configuration
Unstructured DS3 SAM
Table 7-3: Unstructured DS3 SAM Diagnostics Configuration
Network RAI
Auto
X-bits 1
X-bits 0
Indication (RAI) configuration. Allows user configuration of the X-bits
associated with C-bit parity framing. Auto makes it transparent; the other choices
set the X-bits to either 1 or 0.
Service RAI
Auto
X-bits 1
X-bits 0
Indication (RAI) configuration. Allows user configuration of the X-bits
associated with C-bit parity framing. Auto makes it transparent; the other choices
set the X-bits to either 1 or 0.
Item
Options
Comments
Automatic FEAC Alarms
Activate/Deactivate
Activates or deactivates Far End Alarm and
Control Channel (FEAC) alarms. FEAC alarms
can only be active when the port is configured
for C-bit parity framing. Activate to detect and
transmit RAI as applicable and detect FEAC
channel activate/deactivate commands
Network FEAC Loopback
Activate/Deactivate
Activate sends a FEAC command to the far end
network equipment to go into network
loopback. Deactivate sends a FEAC command
to go out of network loopback. Only active
when port is configured for C-bit parity. The
receive code generated is DS3 Out of Frame
(0000000).
Service FEAC Loopback
Activate/Deactivate
Activate sends a FEAC command to the far end
service equipment to go into service loopback.
Deactivate sends a FEAC command to go out
of service loopback. Only active when port is
configured for C-bit parity.
Network BERT Test
Activate/Deactivate
BERT test can only be performed when the
port is configured for C-bit parity framing.
Causes the port to generate a 2e
23
pseudo-
random test pattern to the ATM network.
Service BERT Test
Activate/Deactivate
Same as network BERT test except it goes to
the service equipment. These tests can be
monitored from CAMMI following the
selection sequence: system management
→
monitor activity
→slot statistics→ DS3 SAM
→ Port # → Port Counters
Item
Options
Comments