5-1 Specifications

5

Sp
eci
fic

at

io

ns

5-4

- Digital Laser Sensor LV-N10 Series User's Manual -

*1 The input time is 25 ms (ON) / 25 ms (OFF) only when external calibration input is selected.
*2 Increases 30 mW (1 mA) for HIGH SPEED Mode
*3 When expanding, always install on a DIN rail (installed on the metal plate), and keep the output current to 20 mA / unit or

less. When expanding units, the working ambient temperature will change according to the following conditions:
1 or 2 units connected: - 20 to + 55 °C; 3 to 10 units connected: - 20 to + 50 °C; 11 to 16 units connected: - 20 to + 45 °C
When using the 2 output type, one unit is counted as 2 units.

*4 When connecting 9 or more expansion units, ensure that the power voltage is 20 V or more.
*5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It dose not include the power consumption of the load.

Power consumption when expansion units are connected is the total power consumption of each amplifier unit.
Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in

HIGH SPEED mode.
(1.15

×

860 mW

Ч

1) + (1.15

Ч

860 mW

×

2) = max. 2967 mW

*6 Use with the over current protection device which is rated 30 V or more and not more than 1 A.

Sensor Amplifier

Type

2 output

1 output

0-line

Monitor output

Cable / Connector

Cable

M8 connector

Cable

Main unit / Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Expansion unit

Main unit

Model

NPN

LV-N11N

LV-N12N

LV-N11CN

LV-N12CN

LV-N10

LV-N11MN

PNP

LV-N11P

LV-N12P

LV-N11CP

LV-N12CP

Input/output

Control output

2 output

1 output

N/A

1 output

External input

1 input

1 input

N/A

1 input

Monitor output

N/A

1 output

Response time

80 øs (HIGH SPEED) / 250 øs (FINE) / 500 øs (TURBO) / 1 ms (SUPER) /4 ms (ULTRA) / 16 ms (MEGA)

* 80 øs cannot be selected when LV-S31 / S62 / S63 is connected.

Output operation

Light-ON / Dark-ON switch

Timer function

Timer OFF, OFF delay, ON delay, One-shot

Timer variable (1 ms to 9999 ms) Maximum error to setting value is μ 10% or less

Control output

NPN output

NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) /

2 V or less (Output current: 10 to 100 mA)

(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less

(Multiple connections) 1 output max: 20 mA or less

PNP output

PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) /

2.2 V or less (Output current: 10 to 100 mA)

(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less

(Multiple connections) 1 output max: 20 mA or less

Monitor output (Only LV-N11MN)

Voltage output: 1 to 5 V, load resistance: 10 k

Ω

or more,

repeat accuracy: μ 0.5% of F.S.

Response time: 1ms (HIGH SPEED / FINE / TURBO),1.2 ms (SUPER), 1.8 ms (ULTRA), 4.2 ms (MEGA)

External input

Input time 2 ms (ON) / 20 ms (OFF) or more

*1

Expansion units

Up to 17 units can be connected in total. (The 2-output type is treated as 2 units.)

Protection circuit

Protection against reverse power connection, output overcurrent, and output surge

Number of
interference
prevention
units

Connect with
other than LV-S31

HIGH SPEED: 0, FINE / TURBO / SUPER: 2, ULTRA / MEGA: 4

(These numbers double when "Double" is selected.)

Connect with
LV-S31

FINE: 2, TURBO / SUPER / ULTRA / MEGA: 4 (These numbers double when "Double" is selected.)

Ra
te

d

Power voltage

*4

24 VDC (operating voltage 10 to 30 VDC (including ripple)), ripple (P-P) 10% or less, Class 2 or LPS

*6

Power
consump-
tion

*5

NPN

Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)

*2

Eco on: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)

*2

Eco full: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)

PNP

Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)

*2

Eco on: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)

*2

Eco full: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)

Environmen-
tal resistance

Ambient
temperature

- 20 °C to + 55 °C (no freezing)

*3

Relative humidity

35 to 85% RH (no condensation)

Vibration

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of X, Y, Z axes

Shock resistance

500 m/s

2

, 3 times for each X, Y, Z axis direction

Material

Housing

Amplifier body and dust cover material: Polycarbonate

Cable

PVC

Housing dimensions

H 32.6 mm

× W 9.8 mm × L78.7 mm

Weight

Approx. 75 g

Approx. 65 g

Approx. 20 g

Approx. 20 g

Approx. 20 g

Approx.75 g