beautypg.com

Interference prevention, Interference prevention -31 – KEYENCE LV-N10 Series User Manual

Page 79

background image

4-5 System Settings (SYS)

4

Set

tings
for Ad

van
c

ed Fu

nct
ion
s

4-31

- Digital Laser Sensor LV-N10 Series User's Manual -

Malfunction may result from "interference", a phenomenon in which light transmission
occurs simultaneously with any other sensor amplifier.
However, when the number of sensor amplifiers increases, the light transmission
timing automatically shifts and prevents this interference.
Setting this function to "dobL" (Double) on all of the connected amplifier units doubles
the number units that do not mutually interfere.

• Selecting "dobL" also doubles response time over the Std state.
• When selecting "
dobL", the main unit and its connected expansion

units must all be set to "dobL".

• This function does not work if the eco function is set to

"FuLL"(Full).

• If the number of interference prevention units is set to Std, the number of

units that do not interfere when the LV-N10 Series main unit and expan-
sion units connected will be as follows. If set to dobL, the number of units
that do not interfere will be doubled.
When unit other than LV-S31 is connected: 0 units for HIGH SPEED, 2
units for FINE/TURBO/SUPER, and 4 units for ULTRA/MEGA.
When LV-S31 is connected: 2 units for FINE, and 4 units for TURBO/
SUPER/ULTRA/MEGA.

• Consult with KEYENCE for the interference prevention when using the

LV-N10 Series together with other series.

Interference Prevention

Refer to page 4-2 "System Settings (SYS)" for setting methods.

Display

Function

Std (Standard)

Normal operation (Default)

dobL (Double)

The interference prevention doubles over the Standard
state.

Point

Reference