Quick Reference

The main setting operations are explained according to purpose. Refer to Chapter 4
for information on advanced function settings and explanations not given below.

Purpose

Description

Operation procedures

Reference

page

Changing the

output

1

Change the output. (L-on/D-on)

1. Press the [MODE] button.

2. Switch with the

(

) button.

3-4

Adjusting the

sensitivity and
integrating the

display to "100.0"

and ".0"

2

Set the current received light intensity
to "100.0". (Preset)

Reflective model: Press the [PRESET] button
when a workpiece is present. Thrubeam/Retro-
reflective model: Press the [PRESET] button
when no workpiece is present.

3-6

3

When preset is valid, register the
received light intensity ".0".
(Work-preset)

After step 2, press the [PRESET] button +
button in the state to be set as ".0".

3-7

4

Set the received light intensity slightly
higher than when the setting was
made, to "100.0". (Maximum sensitiv-
ity preset)

While the PST indicator is OFF, press and hold
the [PRESET] button. Reflective model: When
no workpiece is present. Thrubeam/Retro-
reflective model: When a workpiece is present.

3-8

5

Automatically register "100.0" and ".0"
when workpiece passes by. (Full Auto
preset)

Press and hold the [PRESET] button while the
PST indicator is OFF.

3-9

6

Cancel the various preset functions.

Press and hold the [PRESET] button.

3-6

7

Set the display for preset execution to
"1000" (LV-NH100/NH110) or "3000"
(LV-NH300). (Preset area display
mode)

1. Press and hold the [MODE] button,

but-

ton and [SET] button simultaneously.
2. Press the [MODE] button.

3. Select "Pr-d ArEA" with

(

) button, and

press and hold the [MODE] button.

3-11

Adjusting the

sensitivity

8

Set the setting value at the midpoint
between the received light intensity
values when a workpiece is present
and absent. (2-point calibration)

1. Press the [SET] button once when a work-
piece is present.
2. Press the [SET] button once when no work-
piece is present.

3-12

9

Set the setting value slightly higher
than the received light intensity value
at which the setting was made. (Maxi-
mum sensitivity calibration)

Reflective model: Press and hold the [SET] but-
ton when no workpiece is present. Thrubeam/
Retro-reflective model: Press and hold the
[SET] button when a workpiece is present.

3-13

10

Set the setting value automatically
when a workpiece is passing through.
(Full auto calibration)

Press and hold the [SET] button while the work-
piece passes through.

3-14

11

Set the setting value to the base point
where the workpiece is positioned.
(Positioning calibration)

1. Press the [SET] button once when no work-
piece is present.
2. Press and hold the [SET] button at the posi-
tioning point.

3-15

12

Finely adjust the setting value directly.

Press the

(

) button.

1-5

Shifting the

received light

intensity to ."0"

13

Set the current display to ."0". (Zero
shift)

Press the [PRESET] button +

button when

the PST indicator is OFF.

3-17

14

Cancel the zero shift function.

Press and hold the [PRESET] button.